Log Book for May 13, 2005
Engineering Report
Natalie Cutler Reporting

Time Battery
Voltage
Current
Load
Generator
on?
10:00 23.2V 5A No
19:00 26.7V 5A Yes
Generator/Electricity:

Casper restarted at 10:00 reading 2226.7hrs. Oil level half full, topped up. Generator run all day. Will be stopped before midnight. At 19:00 reading 2235.6hrs. Before departure tomorrow, Inverter will be switched off also as instructed by Engineering Team.

At 19:00:
Casper Generator Oil Pressure: 40
Generator battery voltage: low in 'green' range

Fuel Status:

Gasoline containers (5gal): 7x full, 4x empty. Blue truck fuel tank will be filled with gasoline tomorrow, and remaining gasoline containers placed in back of truck. Please confirm that no gasoline needs to be left at MDRS.

Diesel Fuel Bottles: 2x full

Oil Bottles:
  • Grade=30: 6x full, 1x quarter full
  • Grade=20-50: 1x half full
  • Grade=5-30: 1x full

    Generator Main fuel tank: between half and three quarters full
    Propane tank: 45.5%

    Water Status:

    Internal Tank:
    At 14:15 level was 22gal, refilled to 50gal.
    At 20:15 level was 32gal. Total water used = 18gal.

    Water Meter Change:
    At 14:15 meter read 2468.0.
    At 20:15 meter read 2485.9.
    Total water usage = 17.9gal.
    External water tank: 24 inches on deeper side
    Flushes: 5
    Showers: 1 (5 more later tonight, we haven't had time with the film crew here)

    Transportation: All three ATVs used for both EVAs today. All three tanks read three quarters full at end of day. Not refilled. ATV Fuel will be switched off tomorrow morning before we leave. Keys will be given to Don. Rear left tire on ATV #1 a little low this morning. Pumped up before first EVA. Fine for second EVA. Rear left tire on ATV #2 pressure ok. Pressurised Rover: Not used. Coolant and oil will be checked tomorrow morning before departure.

    Mars Suits: Potting of PLSS #5, 2, 4 complete. Others will be potted tonight if time permits as these were out on EVA in the morning and afternoon. Problem with PLSS#5 fan traced to faulty fuse connection. Needs to be replaced. Suit gloves will be sent to Don for washing.

    HVAC: Heating used late last night for 1hr.

    Computers & Network: Operational.

    GreenHab:
  • Tank #1: Full, but not flowing to next tank
  • Tank #2: 1 inch low
  • Tank #3: Full, but not flowing to next tank
  • Tank #4: 2 inches too low
  • Tank #5: Half full
  • TST still in Tank #4 as Tank #5 too low for pump to reach water level.
    Crew comments that the toilet flush water is finally looking clear rather than green!

    Miscellaneous: Have not had time to measure levelness of the shower floor. But it's definitely not level. Noticed that there is no power to the outlets in the shower room. Seems they are not connected. Just thought we'd let you know.